Loading...
HomeMy WebLinkAboutX2020-1608 - CalcsAOX ENGINEERING 1520 Brookhollow, Suite #45, Santa Ana, CA 92705 Tel: (714) 662 0510 Fax: (714) 662 0559 a „/)0 -1 o y MCI w Oal Ave% STRUCTURAL CALCULATIONS for Marvin Residence 1209 W. Bay Ave. NEWPORT BEACH CA ,92661 o� 5� MK20-29 �s�� 9-Jul-20 S�Q QROFESS/pN NG X/ �yc C.; N0. a S. 5289 EXP. 6/30/il42 �„ tial AQX ENGINEERING Residential Roof Design Loads Description Comp. sh 5.0 psf 1/2" plywood sheathing 1.5 psf Gyp Board Ceiling 3.0 psf Roof Framing 2.5 psf Ceiling framing 2.0 psf Insul. Misc. 1.0 psf 15.0 psf 15.0 psf Slope: 4 :12 Adjustment: 1.054 USE: 15.8 psf Say 16.0 psf Live Load: (Method 11 0 to 200sgt USE Flat or rise < =4:12 20 Rise = 6:12 18 Rise >12:12 16 Wall weight breakdown Description with Plaster gypsum board 1/2" 2.2 psf 2x6 studs@16"o.c.- 2 walls 3.4 psf Insulation 0.5 psf 8.0 psf stucco Mechanical/Electrical 0.5 psf Subtotal 14.6 psf Use Ext. with stucco 15.0 psf 201 to 600 act Over 600 act 16 12 psf 16 12 psf 12 12 psf Int. 9 psf 261 USE USE AQX ENGINEERING suite Residential Floor Design Loads Description Living Spaces Carpet 1.5 psf Plywood sheathing 3.8 psf Framing 4.0 psf MEP 1.0 psf 5/8 gyp Bid ceiling(2) 2.8 psf Insulation & Misc 1.0 psf Total 14.1 psf USE 14.0 psf Live load 40 psf Deck 60 psf Calculation Sheet Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: Project Descr and then using the "Printing & Max fb/Fb Ratio Title Block" selection. Title Block Line 6 Printed: 23 SEP 2020, 8:32AM File: MARVIN-MK20-29.ec6 Multiple Simple Beam - Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.17 Description: THE MAIN HOUSE Wood Beam Design: BM1 Calculations per NDS 2018, IBC 2016, CBC 2019, ASCE 7-16 BEAM Size: 8.75x10.5, GLB, Fully Unbraced Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: DF/DF Wood Grade: 24F -V4 Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800 ksi Density 31.21 pct Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950 ksi Applied Loads 5112 Unit Load: D = 0.0140, L = 0.040 k/ft, Trib= 1.330 fi Unit Load: D = 0.0140, L = 0.040 k/ft, Trib=1.330 IN = 1.60, L = 2.50 k @ 0.50 ft Design Summary Point: D=1.40, Lr=2.10k@14.0ft Max fb/Fb Ratio = 0.194: 1 Design Summary 552.68 psi at 0.500 ft in Span # 1 Fb: Allowable: Max fb/Fb Ratio = 0.261 : 1 D(o.o1862)- .(0.053zo)- fb : Actual : 765.48 psi at 14.000 ft in Span # 1 Max fv/FvRatio = 0.090: 1 Fb: Allowable: 2,934.99 psi 8.75x10.5 Fv: Allowable: Load Comb: +D+Lr+H Load Comb: +D+L+H Max fv/FvRatio = 0.145: 1 17.50 e Left Support fv : Actual : 48.13 psi at 16.683 ft in Span # 1 Right Support 0.25 0.37 0.13 Fv: Allowable: 331.25 psi Load Comb: +D+Lr+H Max Deflections Max Reactions (k) D L Lr S W E H Transient Downward 0.155 in Total Downward 0.300 in Left Support 0.44 0.47 0.42 Ratio 1353 Ratio 699 Right Support 1.28 0.47 1.68 LC: Lr Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: BM2 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 3.5x9.25, Parallam PSL, Fully Unbraced Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species : il-evel Truss Joist Wood Grade : Parallam PSL 2.0E Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 45.070 pcf Fb - Compr 2,900.0 psi Fc- Perp 750.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 ksi Applied Loads 5112 Unit Load: D = 0.0140, L = 0.040 k/ft, Trib= 1.330 fi Point: D = 2.30, Lr = 1.60, L = 2.50 k @ 0.50 ft Design Summary Transient Upward Max fb/Fb Ratio = 0.194: 1 fb : Actual : 552.68 psi at 0.500 ft in Span # 1 Fb: Allowable: 2,850.93 psi Load Comb: +D+L+H Max fv/FvRatio = 0.090: 1 fv : Actual : 25.99 psi at 5.240 ft in Span # 1 Fv: Allowable: 290.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr 8 W E Left Support 2.16 2.45 1.47 Right Support 0.25 0.37 0.13 D(0_018) L(o.05320) y 3.5xe25 !w e.0 tt Max Transient Ds H Transient Downward 0.014 in Total Downward 0.027 in Ratio 5112 Ratio 2687 LC: L Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block' selection. Title Block Line 6 Multiple Simple Beam Project Title: Engineer: Project ID: Project Descr: Software Printed: 23 SEP 2020, 8:32AM INC. 1 Wood Beam Design : BM3 Total Downward 0.557 in Unif Load: D = 0.0140, L = 0.040 k/ft, Trib= 9.0 ft Point: D = 1.40, Lr = 2.10 k @ 14.0 ft Design Summary Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 10.50 X 9.50, Parallam PSL, Fully Unbraced 1,250.00 psf at 8.216 ft in Span # 1 Fb: Allowable: Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: DF/DF Max fv/FvRatio = Wood Grade: 24F -V4 Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800 ksi Density 31.21 pcf Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950 ksi Applied Loads Total Downward 0.557 in Unif Load: D = 0.0140, L = 0.040 k/ft, Trib= 9.0 ft Point: D = 1.40, Lr = 2.10 k @ 14.0 ft Design Summary 555 Max fb/Fb Ratio = 0.521- 1 Po : Actual : 1,250.00 psf at 8.216 ft in Span # 1 Fb: Allowable: 2,400.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.266: 1 fv : Actual : 70.62 psi at 15.010 ft in Span # 1 Fv: Allowable: 265.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr 5 W E Left Support 1.15 2.84 0.24 Right Support 2.24 2.84 1.86 Wood Beam Design : BM4 Using Allowable Stress Design Wood Species : Douglas Fir -Larch Fb - Tension 1350 psi Fc - Prll Fb - Compr 1350 psi Fc - Perp Applied Loads Unif Load: D=0.0160, Lr = 0.020 k/ft, Trib= 6.0 fl Design Summary Max fb/Fb Ratio = 0.416. 1 D(0.1260) L(p-360) Jima 10.50X9.50 15.60 ft H Transient Downward 0.376 in Total Downward 0.557 in Ratio 504 Ratio 340 555 LC: L Only Load Comb: LC: +D+L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 at LC: Fv : Allowable: LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 IBC 2018 Load Combinations, Major Axis Bending Wood Grade : No.1 925 psi Fv 170 psi Ebend-xx 625 psi Ft 675 psi Eminbend - xx Po : Actual : 899.70 psi at 3.500 ft in Span # 1 Fb : Allowable : 2,164.11 psi 555 Load Comb: +D+Lr+H Transient Upward Max fv/FvRatio = 0.242: 1 Ratio fv : Actual : 51.45 psi at 6.557 ft in Span # 1 Fv : Allowable: 212.50 psi LC: Load Comb: +D+Lr+H Max Reactions (k) D L Lr S W E Left Support 0.34 0.42 Right Support 0.34 0.42 1600 ksi Density 31.21 pcf 580 ksi O(0.0960) Lr(0.120) 4x6 4 7.0 ft H Transient Downward 0.084 in Total Downward 0.151 in Ratio 1000 Ratio 555 LC: Lr Only LC: +D+Lr+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: AQX ENGINEERING 1520 Brookhollow, Suite #45, Santa Ana, CA 92705 Tel: (714) 662 0510 Fax: (714) 662 0559 —:4z STRUCTURAL CALCULATIONS for Marvin Residence 1209 W. Bay Ave. NEWPORT BEACH CA ,92661 MK20-29 9 -Jul -20 No. S. 5289 EXP. 6130/}62 AQX ENGINEERING Tel: (9491261 7740 1520 Brookhollow. suite #45. Santa Ana. CA 92705 Fax: (9491 261 7760 JOB NAME I JOB NG SHEET N0: ADDRESS: I ENGINEER: Mandl DATE: Residential Roof Design Loads Description Comp. sh 5.0 psf 1/2" plywood sheathing 1.5 psf Gyp Board Ceiling 3.0 psf Roof Framing 2.5 psf Ceiling framing 2.0 psf Insul. Misc. 1.0 psf 15.0 psf 15.0 psf Slope: 4 :12 Adjustment: 1.054 USE: 15.8 psf Say 16.0 psf Live Load: (Method 1) with Plaster gypsum board 1/2" 2.2 psf 2x6 studs@16"o.c.- 2 walls 3.4 psf Insulation 0.5 psf stucco 0 to 200sgt 201 to 600 sot Over 600 sot USE Flat or rise <=4:12 20 16 12 psf Rise = 6:12 18 16 12 psf Rise > 12:12 16 12 12 psf Wall weight breakdown Descriotion with Plaster gypsum board 1/2" 2.2 psf 2x6 studs@16"o.c.- 2 walls 3.4 psf Insulation 0.5 psf stucco 8.0 psf Mechanical/Electrical 0.5 psf Subtotal 14.6 psf Use Ext. with stucco 15.0 psf Int. 9 psf AQX ENGINEERING Tel: (9491261 7740 1520 Brookhollow. suite 1145. Santa Ana. CA 92705 Fax: (949)261 7760 JOB NAME: I JOB NO: SHEET NO: ADDRESS: I ENGINEER: Mandi DATE: Residential Floor Design Loads Dead Loads: Description Carpet Plywood sheathing Framing MEP 5/8 gyp. Bd ceiling(2) Insulation & Misc Total USE Live Load: Living Spaces 1.5 psf 3.8 psf 4.0 psf 1.0 psf 2.8 psf 1.0 psf 14.1 psf 14.0 psi USE Live load 40 psf USE Deck 60 psf AQX ENGINEERING PROJECT: SHEET NO.: 1520 Brookholiow, Suite #45, Santa Ana DESIGNED BY:Mand1 I CHECKED BY: JOB NO.: Tei: (714) 662 0510 DATE: DATE: Fax: (714) 662 0559 Description: [moi t rdX_I .. P �Z • PA waV"q e 7ft- tFm)SM Jim f—r-t 35LIZ+!2 m5 W1 CelrulnFlnn c6ed Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Multiple Simple Beam Project Title: Engineer: Project ID: Project Descr: Printed: 23 SEP 2020, 8:32AM File: MARVIN-MK20-29,ec6 INC. 1983-2020, Build:12.20.8.17 Description: THE MAIN HOUSE Wood Beam Design: BM1 Calculations per Nos 2018, IBC 2018, CBC 2019, ASCE 7-16 Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: DF/DF Wood Grade : 24F -V4 Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800 ksi Density 31.21 pcf Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950 ksi Applied Loads Unif Load: D = 0.0140, L = 0.040 k/ft, Trib= 1.330 fl Point: D=1.40, Lr=2.10k@14.0fi Design Summary Max fb/Fb Ratio = 0.261 ; 1 fb : Actual : 765.48 psi at 14.000 ft in Span # 1 Fb : Allowable: 2,934.99 psi Load Comb: +D+Lr+H Max fv/FvRatio = 0.145: 1 fv : Actual : 48.13 psi at 16.683 ft in Span # 1 Fv: Allowable: 331.25 psi Load Comb: +D+Lr+H Max Reactions (k) D L Lr S W E LeftSupport 0.44 0.47 0.42 Right Support 1.28 0.47 1.68 INEW 0-- 8.75x1p.5 A, 17.50 It Transient Downward 0.155 in Ratio 1353 LC: Lr Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.300 in Ratio 699 C: +D+0.750Lr+0.750L+H Total Upward 0.000 in Ratio 9999 LC: Wood Beam Design: BM2 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 3.5x9.25, Parallam PSL, Fully Unbraced Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species : Level Truss Joist Wood Grade: Parallam PSL 2.0E Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 45.070 pcf Fb-Compr 2,900.0 psi Fc - Perp 750.0 psi Ft 2,025.0 psi Eminbend -xx 1,016.54 ksi Applied Loads Total Downward Unif Load: D = 0.0140, L = 0.040 k/ft, Trib=1.330 fi Point: D = 2.30, Lr =1.60, L = 2.50 k @ 0.50 fi Design Summary Max fb/Fb Ratio = 0.194: 1 fb : Actual : 552.68 psi at 0.500 ft Fb : Allowable: 2,850.93 psi Load Comb: +D+L+H Max fv/FvRatio = 0.090: 1 fv : Actual : 25.99 psi at 5.240 ft Fv: Allowable : 290.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr 8 Left Support 2.16 2.45 1.47 Right Support 0.25 0.37 0.13 in Span # 1 D(D.01862) t._tD.053201__,. 3.5x9.25 e; in Span # 1 _ ..6.0 It W_ E H Transient Downward 0.014 in Total Downward 0.027 in Ratio 5112 Ratio 2687 LC: L Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: - Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. fb : Actual : Title Block Line 6 Printed: 23 SEP 2020, 8:32AM MUltl le Simple Beam p p File: MARVIN-MK20-29.ec6 +D+L+H Software copyright ENERCALC, INC. 1983-2020, Build;12.20.8.17 .11. 1 P Wood Beam Design: BM3 Fv: Allowable: 265.00 psi Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 10.50 X 9.50, Parallarn PSL, Fully Unbraced Transient Upward 0.000 in Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: DF/DF Wood Grade: 24F -V4 Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx 1800 ksi Density 31.21 pcf Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx 950 ksi Aoolied Loads L Unif Load: D = 0.0140, L = 0.040 k/ft, Trib= 9.0 fl Point: D=1.40, Lr=2.10k@14.0ft Total Downward 0.557 in Design Summary 2.84 Max fb/Fb Ratio = 0.521 • 1 fb : Actual : 1,250.00 psi at 8.216 ft in Span # 1 Fb : Allowable: 2,400.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.266: 1 fv : Actual : 70.62 psi at 15.010 ft in Span # 1 Fv: Allowable: 265.00 psi Load Comb: +D+L+H D(0.1260) L(0.360) 10.50 x 9.50 15.80 ft Max Reactions (k) D L Lr S W E H Transient Downward 0.376 in Total Downward 0.557 in Left Support 1.15 2.84 0.24 Ratio 504 Ratio 340 Right Support 2.24 2.84 1.86 0.242: 1 9999 fv : Actual : 51.45 psi LC: L Only LC: +D+L+H Fv: Allowable: 212.50 psi Transient Upward 0.000 in Total Upward 0.000 in +D+Lr+H Ratio 9999 Ratio 9999 Lr S W E Left Support LC: LC: Wood Beam Design: BM4 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 BEAM Size: 4x6, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: Douglas Fir -Larch Wood Grade: No.1 Fb - Tension 1350 psi Fc - Prll 925 psi Fv 170 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 1350 psi Fc - Perp 625 psi Ft 675 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0160, Lr = 0.020 k/ft, Trib= 6.0 fl Design Summary Max fb/Fb Ratio = 0.416. 1 fb : Actual : 899.70 psi' at 3.500 ft in Span # 1 Fb : Allowable : 2,164.11 psi LC: Lr Only Load Comb: +D+Lr+H Transient Upward 0.000 in Max fv/FvRatio = 0.242: 1 9999 fv : Actual : 51.45 psi at 6.557 ft in Span # 1 Fv: Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L Lr S W E Left Support 0.34 0.42 Right Support 0.34 0.42 1)(0.0960) Lr(0.120)_ A, 4x6 7.0 ft H Transient Downward 0.084 in Total Downward 0.151 in Ratio 1000 Ratio 555 LC: Lr Only LC: +D+Lr+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: �= O ENGINE �Z y 1520 el: 1 olloW suite 45 ERjNG Tel: (714) 662 0510 Fax Santa An 9 (714) 662 C 2705 0559 STRUCTURAL CAL for CULATIONS Marvin Residence IVEWPO 09 W. BV A ve. ET BEACH CA ,92661 MK20.29 9 -Jul -20 BWL°tN° olwalom JUL 7 2020 ft,v AQX ENGINEERING Residential Roof Design Loads Dead Loads Description with plaster gypsum board 2.2 psf Comp. sh 5.0 psf Insulation 0.5 psf 8.0 psf 1/2" plywood sheathing 1.5 psf Subtotal 14.6 psf Gyp Board Ceiling 3.0 psf Use Ext. with stucco 0 Roof Framing 2.5 psf Ceiling framing 2.0 psf Insul. Misc. 1.0 psf 15.0 psf 15.0 psf Slope: 4 :12 Adjustment: 1.054 15.8 psfSa_�f USE: Live Load: Method 1 0 to 200sgt 201 to 600 sot Over 600 sqt 16 12 psf USE Flat or rise < =4:12 20 16 12 psf Rise = 6:12 18 12 12 psf Rise> 12:12 16 Wall weight breakdown Description with plaster gypsum board 2.2 psf o.c. 2x6 studs@16"o.c: 2 walls 3.4 psf Insulation 0.5 psf 8.0 psf stucco Mechanical/Electrical 0.5 psf Subtotal 14.6 psf 15.0 psf Int. g psf Use Ext. with stucco 0 i I T01: '9 '4 261 7740 .JOB NAI ME: I USE USE AQX ENGINEERING Residential Floor Design Loads Description Living Spaces Carpet 1.5 psf Plywood sheathing 3.8 psf Framing 4.0 psf MEP 1.0 psi 5/8 gyp.Bd ceiling(2) 2.8 psf Insulation & Misc 1.0 psf Total 14.1 psf USE 14.0 psf Live load 40 psf Deck 60 psf TE: Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project DeSCC Title Block" selection. 45.070 pcf Title Block Line 6 Printed: 9 JUL 2020, 10 15A Multiple Simple Beam FIM- 120-29..36 Applied Loads -20, Bu d:1220.5.31 .Software copyright ENERCALC, INC. 190 (tion: THE MAIN HOUSE Beam Design: BM1 Calculations per NDS IBC 2016, CBC 2019, ASCE 7-16 Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending 552.68 psi Wood Species : iLevel Truss Joist 0.500 It in Span # 1 Wood Grade: Parallam PSL 2.0E 2,850.93 psi Fb - Tension 2,900.0 psi Fc - Prll 2,900.0 psi Fv 290.0 psi Ebend- m 2,000.0 ksi Density 45.070 pcf Fb -Compr 2,900.0 psi Fc - Perp 750.0 psi Ft 2,025.0 psi Eminbend-xx 1,016.54ksi 0.090: Applied Loads fv : Actual : 25.99 psi Unif Load: D = 0.0140, L = 0.040 k/ft, Trib=10.0 ft 5.240 ft in Span # 1 Fv: Allowable: 290.00 psi Point: D=1.80, Lr = 2.0 k @ 7.0 It Ratio Load Comb: +D+L+H Point: D=0.40, Lr = 0.40 k @ 12.50 ft Max Reactions (k) D L Design Summary S W E - 2.16 2.45 Max fb/Fb Ratio = 0.665. 1 gto.140f L(o:ao) 0.25 0.37 fb : Actual: 1,916.08 psf at 7.000 ft in Span # 1 Fb : Allowable : 2,879.80 psi Load Comb: +D+L+H 7x9.25 Max fv/FvRatio = 0.318: 1 12.50 ft fv : Actual: 92.15 psi at 11.750 ft in Span # 1 Fv: Allowable: 290.00 psi Load Comb: +D+L+H Max Deflections Max Reactions (k) D L Lr s w E H Transient Downward 0.239 in Total Downward 0.511 in Left Support 1.67 2.50 0.88 Ratio 627 Ratio 293 Right Support 2.28 2.50 1.52 LC: L Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: BM2 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Wood Species : iLevel Truss Joist Fb- Tension 2,900.0 psi Fc -Prll Fb - Compr 2,900.0 psi Fc - Perp Applied Loads Unif Load: D = 0.0140, L = 0.040 k/ft, Trib=1.330 fl Point: D=2.30, Lr 1.60, L = 2.50 k @ 0.50 fl Design Summary Max fb/Fb Ratio = 0.194; 1 h IBC 2018 Load Combinations, Major Axis Bending Wood Grade: Parallam PSL 2.0E 2,900.0 psi Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 45.070 pcf 750.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 ksi fb : Actual: 552.68 psi at 0.500 It in Span # 1 Fb: Allowable: 2,850.93 psi Load Comb: +D+L+H 0.027 in Ratio Max fv/FvRatio = 0.090: 1 fv : Actual : 25.99 psi at 5.240 ft in Span # 1 Fv: Allowable: 290.00 psi 0.000 in Ratio Load Comb: +D+L+H 9999 Max Reactions (k) D L Lr S W E Left Support 2.16 2.45 1.47 Right Support 0.25 0.37 0.13 010.01962/. L(p.05320) 3.5x9.25 6.0 it Max Deflections H Transient Downward 0.014 in Total Downward 0.027 in Ratio 5112 Ratio 2687 LC: L Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LG LC: Title Block Line 1 Project Title: You can change this area Engineer: using the "Settings" menu item Project escr: Project D and then using the "Printing 8 2,900.0 psi Fc - Perp 750.0 psi Title Block" selection. Printed: 9 JUL 2020, 10 15A Title Block Line 6 File: MARVIN-M 0-29.ec6 Multiple .Simple Beam Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.5.31 Beam Design: BM3 BEAM Size: 10.50 X 9.250, Parallam PSL, cull Ur Using Allowable Stress Design with IBC 22018 Wood Species: iLevel Truss Joist Fb- Tension 2,900.0 psi Fc -Prll 2,900.0 psi Fb - Compr 2,900.0 psi Fc - Perp 750.0 psi Applied Loads Design Summary Unif Load: D = 0.0140, L = 0.040 k/ft, Trib=10.0 It Point: D=1.80, Lr=2.0k@7.0It Point: D=0.30, L=0.50k@12.50ft Design Summary fv : Actual: Max fb/Fb Ratio = 0.593; 1 fid : Actual: 1,719.80 psi at 7.008 ft in Span # 1 Fb: Allowable: 2,900.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.271; 1 fv : Actual: 78.49 psi at 13.775 ft in Span # 1 Fv: Allowable: 290.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr S W E Left Support 1.99 2.97 1.03 Right Support 2.14 3.33 0.97 Beam Design' BM4 Wood Species : Douglas Fir -Larch Fb- Tension 1350 psi Fc-Prll Fb - Compr 1350 psi Fc - Perp Applied Loads 9999 Unif Load: D=0.0160, Lr= 0.020 k/ft, Trib= 6.0 fi Design Summary Max fb/Fb Ratio = 0 416 1 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 rwu d Combinations, Major Axis Bending Wood Grade: Parallam PSL 2.0E Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 45.070 pcf Ft 2,025.0 psi Eminbend -xx 1,016.54ksi D(0.140j L(O 40). 10.50 X 9.250 Ilk 14.50 ft Max De actions 11 Transient Downward 0.305 in Total Downward 0.602 in Ratio 570 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Calculations per NDS as with IBC 2018 Load Combinations, Major Axis Bending Wood Grade: No.1 925 psi Fv 170 psi Ebend- xx 625 psi Ft 675 psi Eminbend - xx fb : Actual: 899.70 psi at 3.500 ft in Span # 1 Fb : Allowable: 2,164.11 psi 9999 Load Comb: +D+Lr+H Max fv/FvRatio = 0.242: 1 fv : Actual: 51.45 psi at 6.557 ft in Span # 1 Fv: Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L Lr a W E Left Support 0.34 0.42 Right Support 0.34 0.42 Ratio 289 C: +D+0.750Lr+0.750L+H Total Upward 0.000 in Ratio 9999 LC: IBC 2018, CBC 2019, ASCE 7-16 1600 ksi Density 31.21 pcf 580 ksi Ratio 1000 Ratio 555 LC: Lr Only LC: +D+Lr+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: I . - 4 AQX ENGINEERING k2 1520 Brookhollow, Suite #45, Santa Ana, CA 92705 Tel: (714) 662 0510 Fax: (714) 662 0559 STRUCTURAL CALCULATIONS for Marvin Residence 1209 W. Bay Ave. NEWPORT BEACH CA ,92661 MK20-29 9 -Jul -20 N0. S. 5289 EXP. 6/30/18 . Z AOX ENGINEERING 1520 Brookhollow, Suite #45, Santa Ana, CA 92705 Tel: (714) 662 0510 Fax: (714) 662 0559 STRUCTURAL CALCULATIONS for Marvin Residence 1209 W. Bay Ave. NEWPORT BEACH CA ,92661 MK20-29 9 -Jul -20 AQX ENGINEERING Residential Roof Design Loads Description Comp. sh 5.0 psf 1.5 psf 1/2" plywood sheathing 3.0 psf Gyp Board Ceiling 2.5 psf Roof Framing 2.0 psf Ceiling framing 1.0 psf Insul. Misc. 8.0 psf stucco 15.0 psf 16 15.0 psf Slope: 4 :12 Adjustment: 1.054 Say 16.0 psf USE: 15.8 psf Live Load: Method 1 with plaster Description Over 600 sqt 2.2 psf 201 to 600 sqt 3.4 psf 2x6 sluds@J611o.c: 2 walls 0 to 200sg1 Insulation 8.0 psf stucco 0.5 psf 16 12 psf USE Flat or rise < =4:12 20 Subtotal 12 psf 15.0 psf 16 Rise = 6:12 18 12 psf 12 Rise> 12:12 16 Wall weight breakdown with plaster Description 2.2 psf gypsum board 112" 3.4 psf 2x6 sluds@J611o.c: 2 walls 0.5 psf Insulation 8.0 psf stucco 0.5 psf Mechanical/Electrical 14.6 psf Subtotal Int. 9 psf 15.0 psf Use Ext. with stucco 261 USE USE AQX ENGINEERING Residential Floor Design Loads Dead Loads: Description Living Spaces Live load 40 psf Deck 60 psf 1.5 psi Carpet 3.8 psf Plywood sheathing 4.0 psf Framing 1.0 psf MEP 518 gyp. Bd ceiling(2) 2.8 psf Insulation & Misc psi 1.0p— 1�.1 psf Total 140 psi USE Live load 40 psf Deck 60 psf Title Flpck Line d You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Multiple Simple Beam (tion: THE MAIN HOi Beam Design: BM1 Project Title: Engineer: Project ID: Project Descr: Printed9 JUL 2020, 10 15A Calculations per NDS 2016, IBC 2018, CBC 2019, ASCE 7-16 BEAM size: 7x9.zo, raranam row,r...y Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species : iLevel Truss Joist Wood Grade : Parallam PSL 2.0E Fb- Tension 2, 900.0 psi Fc - Pill 2,900.0 psi Fv 290.0 psi Ebend-xx 2,000.0 ksi Density 45.070 pcf Fb - Compr 2,900.0 psi Fc - Perp 750.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 ksi Applied Loads Unit Load: D = 0.0140, L = 0.040 Kitt, Trib=10.0 ft Point: D=1.80, Lr=2.0k@7.0ft Point: D=0.40, Lr = 0.40 k @ 12.50 ft Design Summary Max fb/Fb Ratio = 0.665; 1 fb : Actual: 1,916.08 psi at 7.000 ft Fb: Allowable: 2,879.80 psi Load Comb: +D+L+H Max fv/FVRatlO = 0.318: 1 fv : Actual : 92.15 psi at 11.750 ft in Span # 1 Fv : Allowable : 290.00 psi Load Comb + Max Reactions (k) D LLr s_ IN g Left Support 1.67 2.50 0.88 Right Support 2.28 2.50 1.52 D(O.140) L(0.40) in Span # 1 7x9.25 19, 12.50 h IVIax ueuewvna H Transient Downward 0.239 in Total Downward 0.5111 in Ratio 627 Ratio 293 LC: L Only C: +D+0.75OLr+0.750L+H Transient Upward 0.000 in Total Upward 0000000 in Ratio 9999 Ratio LC: LC: Rightt Support LC: Wood Beam Design: BM2 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 3.5x9.zo, raranarnl row, "" Using Allowable Stress Design wit IBC 2018 Load Combinations. GraBending : Pa allamPSL 2.0E Wood Species: iLevel Truss Joist FFb -b - Comprn 2,900.0 psi Fc - Perp 2750.0 00.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 0si Density 45.070 p Applied Loads Unif Load: D=0.0140, L = 0.040 k/ft, Trib=1.330 ft Point: D=2.30, Lr =1.60, L = 2.50 k @ 0.50 ft Design Summary Max fb/Fb Ratio = 0.194; 1 fb :Actual ' 552.68 psi at 0.500 ft in Span # 1 Fb: Allowable: 2,850.93 psi 0200287 in Load Comb: +D+L+H Ratio Max fv/FvRatio = fv : Actual : 0.090:1 25.99 psi at 5.240 ft Fv : Allowable: 290.00 psi 0.000 in Load Comb: +D+L+H Ratio Max Reactions (k) D L Lr S LC: Rightt Support 0.25 0.37 0.13 in Span # 1 z0) n. ( ..3.5x9.25 D 0.01662 L(0 0 6.0 n ax Deflections H Transient Downward 0.014 in Total Downward 0200287 in W E Ratio 5112 Ratio LC: L Only C: +D+0.750Lr+0.750L+H Transient Upward 0.000 in Total Upward 0000000 in Ratio 9999 Ratio LC: LC: Title Flock Line .1 Project Title: You can change this area Engineer: using the "Settings" menu item Project ID: and then using the "Printing & Project Descr: Title Block" selection. Title Block Line 6 Printed: 9 JUL 2020, 10 15A MAR N -M0-29..36 Multiple Simple Beam Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.5.31 Wood Beam Design: BM3 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 10.50 X 9.250, Parallam PSL, Fully Unbraced Using Allowable Stress Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species : il-evel Truss Joist Wood Grade: Parallam PSL 2.0E Fb - Tension 2,900.0 psi Fc - Pill 2,900.0 psi Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 45.070 pcf Fb - Compr 2,900.0 psi Fc - Perp 750.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 ksi Applied Loads Total Downward Unif Load: D=0.0140, L = 0.040 k/ft, Trib=10.0 ft Point: D=1.80. Lr = 2.0 k @ 7.O ft Point: D=0.30, L=0.50k@12.50ft 2,164.11 psi Design Summary C: +D+0.75OLr+0.750L+H Max fb/Fb Ratio = 0.593. 1 fb : Actual : 1,719.80 psi at 7.008 f Fb: Allowable: 2,900.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.271 :1 fv : Actual: 78.49 psi at 13.775 f Fv: Allowable: 290.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr 8 Left Support 1.99 2.97 1.03 Right Support 2.14 3.33 0.97 Wood Beam Design : BM4 in Span # 1 in Span # 1 0 10.50 X 9.250 1450 ft H Transient Downward 0.305 in Total Downward 0.602 in Ratio 570 Ratio 289 2,164.11 psi LC: L Only C: +D+0.75OLr+0.750L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Using Allowable Stiess Design with IBC 2018 Load Combinations, Major Axis Bending Wood Species: Douglas Fir -Larch Wood Grade: No.1 Fb- Tension 1350 psi Fc - Pill 925 psi Fv 170 psi Ebend-xx Fb - Compr 1350 psi Fc - Perp 625 psi Ft 675 psi Eminbend - xx Applied Loads Unif Load: D=0.0160, Lr = 0.020 k9t, Trib= 6.0 fl Design Summary Total Downward Max fb/Fb Ratio = 0.416 fb : Actual : 899.70 psi Fb: Allowable: 2,164.11 psi Load Comb: +D+Lr+H Max fv/FvRatio = 0.242: fv : Actual: 51.45 psi Fv: Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L Left Support 0.34 Right Support 0.34 I at 3.500 ft in Span # 1 1 at 6.557 ft in Span # 1 Lr S IN E 0.42 0.42 1600 ksi Density 31.21 pcf 580 ksi H Transient Downward 0.084 in Total Downward 0.151 in Ratio 1000 Ratio 555 LC: Lr Only LC: +D+Lr+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: