HomeMy WebLinkAboutX2021-2190 - Calcs01 i x2� 010 do �e � Ellias Consulting Engineers 4202 Atlanitc Ave., Suite 209 Phone. (562) 253 2385 Long Beach, CA 90807 Fax: (562) 981-5647 STRUCTURAL CALCULATIONS FOR MARTANO RESIDENCE 1941 COMMODORE RD. NEWPORT BEACH, CA CLIENT Newave Construction Inc. COSTA MESA, CA 92627 August 17, 2021 "Im UnnV TAL➢S fnsfl j4Z Roofing Sheathing Rafters Insulation Ceiling'2" sum Mechanical 6 Fire Sprinklers Other Dead Load Li Ve Load Total Load WALL f f1 psf Framing Framin Exterior Finish 2 GVpsum Board 1/2" Gypsum Insulation/Misc Insula Sheathin Sheath Dead Dead Total 10 WALL DL fnsf) G 02 psf Framin 2.5 Exteri 7 Gypsum 2.5 Insula 0.5 Sheath 2.5 Dead 15 Total 15 G 02 RB1 Grade No.: 2 Species : PSL Full Sawn?: N Load Type (DL,FLR,RF,SNOW) : RF Cn = 125 TRY > 5.25.. x 14 E = 2000 ksi Exact Size = 5.25 in. W. x 14.00 in.dp. Fb = 2900 psi A / S / I = 73.5 in.^2 171.5 in."3 1201 in."4 F„ = 290 psi Po (Ibs) ( from left support) .. 0 .. P, ( Ibs) psi OK Shear R = 0.32 _ Wn (plf) .210 fo = 2768 psi OK W, ( pit) 280 3546 psi Total Load Defl. = 1.85 in. Dist. (ft) 25 1.25 in. 1 1 1 Drop Beam / Header v : N Calculate V @'d'? : Y Deft. Ratio ( L / Input) = 240 CF = 0.98 CL = 1'00 Beam span is ;;center -center support Add 6" to span '; for headers ® 25. ft. Rn, = 2829 RA29 VMGx fibs) = 5707 RLL= 3500 16 plf added to dead load RSR= 3500 at 'd' (in.) = 14.75 RTL= 6329 RTR= 6329 (from left support) Mpos = 39557 ft -lbs at x = 12.50 ft. ( from left support) MNEG = 0 ft-Ibs fv = 116 psi OK Shear R = 0.32 P = 363 psi fo = 2768 psi OK Flexure R = 0.78 Pb = 3546 psi Total Load Defl. = 1.85 in. OK Allowable Deflection = 1.25 in. (Total Load) Live Load Deft. = 1.02 in. OK Width Depth Species Grade RB1 USE > _ . 5.25 x 14 PSL ' 2,0E HDB Grade No.: 2 Shear R = 0.32 RLL= 3500 16 plf added Species : PSL. Full Sawn?: N 11 Load Type (DL,FLR,RF,SNOW) : RF Cn = 125 TRY > 5.25 x 14 E = 2000 ksi Exact Size = 5.25 in. w. x 14.00 in.dp. Fe = 2900 psi A / S / I = 73.5 in ^2 171.5 in."3 1201 in."4 F„ = 290 psi PD Ibs) P, ( Ibs ) W, pff 280 Dist.(ft)=' 25 A 25. ft. Rn, = 2829 Shear R = 0.32 RLL= 3500 16 plf added to dead load R,C- 6329 Fb = 3546 Mpos = 39557 ft -lbs at x = 12.50 ft. fv = 116 psi OK is = 2768 psi OK Total Load Defl. = 1.85 in. OK Live Load Defl. = 1.02 in. OK Drop Beam / Header ? : N Calculate V @ d v : Y Defl. Ratio ( L / Input) = 240 CF = 0.98 CL= 1.00 Beam span is center -center support Add 6" to span for headers RA29 VMnx (Ibs) = 5707 RLR= 3500 at V (in.) = 14.75 R,,= 6329 (from left support) ( from left support) MNEo = 0 ft-Ibs Shear R = 0.32 F'„ = 363 psi Flexure R = 0.78 Fb = 3546 psi Allowable Deflection = 1.25 in. (Total Load) HDBt -USE> .5.25 x 14. "PSL "2.0E WOOD STUD AND POST DESIGN P1 Grade: 2 _ Rr= 0. lbs Kings or Studs?(K,S): P Species ( DF, HF, GLC, PSL ) : DF Full Sawn?: N Defl. Ratio ( L / Input) = Y Axial Load Type (DL,FLR,RF,SNOW, AUTO) : RF Axial Co = 125 Lateral Load Type (AutoW, W, EQ, N/A) : W Lateral Co = 1.25 Basic Co = N/A TRY > 4 x 6 Fb = 875 psi Flexure Cr = 1.3 Exact Size = 3.50 in. w. x 5.50 in.dp. F� = 1350 psi Comp. CF = 1.1 A / S / I = 19.3 in.^2 17.6 in. -3 48.5 in.M E = 1600 ksi CR = 1.00 Roof+Floor Po= 2829 lbs L/D ratio = 21.8 <500K AXIAL LOAD Roof PL= 3500 lbs FcE= 1008 psi Floor PL= lbs Fc` = 1856 psi Dist. ft. Total = 6329 lbs Fc' = 860 psi Wind sf 0 _ Rr= 0. lbs Cc= 1.25 (Governs) 0 (Axial Load Only) f� = 329 psi T Clear Ht. 10. ft. 1 HB2 aring ratio = 0.57 OK 10 (Axial Load Only) Compression R = 0.38 OK Co = N/A Re = 0. lbs Comp. + Bending R = 0.03 OK Meos = 0 ft -lbs at x = 0.00 ft. ( From Bottom Support) fe = 0 psi OK Flexure R = 0.00 F'b = 1422 psi Lateral Load Defl. = 0.00 in. OK Width Depth Species Grade P1 USE> POST 4 x 6 DF 2 PAD FOOTING Allowable Soil Bearing = 1500 psf FOOTING #1 POINT LOAD BEAM R131 6330 lbs 0 lbs TOTAL = 6330 lbs Pad Footing : 25 in