HomeMy WebLinkAboutX2022-0724 - Alternative Material & Methods (5)CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915
www.newoortbeachca.aov 1 (949) 644-3200
CASE NO.:
p4REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $291)
REQUEST FOR ALTERNATE MATERIAL
TTTTT OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $291)
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
JOB ADDRESS:
Plan Check #
RECEllz O
pE 0&41U 6,)-
/ q,4 i Y
✓`/` ` 0<��2T
FOR STAFF USE ONLY IIINr SEACN
Use of Building _
Project Status N
Construction Type _
Verified by
No. of Items
Fee due
DISTRIBUTION:
❑ Owner 59�Plan Check
,E,Petitioner Inspector
❑ Fire ❑ Other
PETITIONER:
SITE ADDRESS: 207 Crystal Avenue Petitioner Christopher Brandon
fo be rohft& or
Owner Doug &Martha Kerstner (l eaaoner aeng/need
Address 151
Address 02 7 Crystal Avenue Costaa Drive. suite G-1
M
Newport Beach. CA zip 92662 Mesa, CA zip 92626
) Daytime Phone (714) 754.4040
Daytime Phone (
attached.
R310
PetitionerPosition Architect
Signature's CA Professional Lic. # C-31637 Date: June 10, 2022
FOR STAFF USE ONLY
DEPARTMENT ACTION: In accordance with: ❑ CBC 104.11/CFC 104.9 .CBC 104.10/CFC 104.8
(Alternate materials d methods) (CBC Modification)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached
By: Date
Request (DOES) ___ OT) lessen any fire protection requirements.
equest (DOES OES NOT Issen the structural integrity
The Request is: Granted ❑Denied (See reverse for appeal information)
El Granted (Ratification required)
Conditions of Approval:
Signature _ — - Position CHIEF BU1i_DING OFFIC O .l Z ] Z✓7�
Print Name
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: REE& 0 XJL197%''ZD-2'2 Fo"Mmodif 07/01/21
it
INT. TRIM
DETAIL PER
F
PLYWOOD - REF. STRUCT.
GYP. BOARD (INTERIOR) EXT. FINISH - REF. DTL. 11, 13, 15/AD-1.0 -
HEADER PER PLAN - REF. CORROSION -RESISTANCE METAL FLASHING
STRUCT. W/. DRIP EDGE PER SIDING MFGR.
(2) LAYERS OF 5/8" MOLD TOUGH VHI FIRECODE'X' BD. OR EO
r
2x SHAPED BILK. VERIFY W/. WINDOW INSTALLER
CAULK & SEAL ALL JOINTS AS RED'D.
NAILING FLANGE PER MFGR.
m
SHIM SPACE PER WDW. MFGR.
o �
WINDOW FRAME /ASSMB'Y. PER MFGR.
HEAD TRIM PROFILE-'AZEK', PER DTL. 6/AD-3.0
WINDOW SILL PROFILE - 'AZEK', PER DTL. 6/AD-3.0 APRON W/. STOOL SLOPED 2% MIN
SHIM SPACE PER WOW. MFGR.
NAILING FLANGE PER MFGR.
CAULK & SEAL ALL JOINTS AS REDO.
I— (2) LAYERS OF 5/8" MOLD TOUGH VHI FIRECODE'X BD. OR E0.
2x FRAMING - PER PLAN
BUILDING WRAP & MOISTURE BARRIER
PLYWD. SHT'G. PER STRUCT.
A
W
I 0
I
I
I
I
I
a IN
I
I
I
m
m
-I
O
0
u
It
Ci N <E;
N
2'-5"
CLR.
I
W
o
I
� y
z
I
N
I
I
W
O
I
3' - 0'
W
A
z
\
I
� N
W
I