HomeMy WebLinkAboutS2023-0147 - MiscCity of Newport Beach Special Inspector Manual
CITY OF NEWPO T BEACH
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION
100 Civic Center Drive I P.O. Box 17681 Newport Beach, CA 92668
www.newportbeachca.gov 1 (949) 644-3200
SPECIAL INSPECTION REPORT
Project Address:1522 PEGASUS ST _
Permit Number: S2023-0147
Inspection Type (s): SHOTCRETE FOR POOL
Inspection Date (s): 9/13/23 (X) Periodic { ) Continuous
To the best of my knowledge, the work Inspected was in accordance with the Building Division approved design drawings,
specifications and applicable workmanship provisions of the U.B.C, except as noted above,
Ben McCarth
SnedallnsnectionReoort 08/25/2015
9/13/23
NB-0713
67
23/241
CHRISTOPHER JEAN & ASSOCIATES, INC.
ACOUSTICAL CONSULTING SERVICES
November 14, 2023 Business License: #BT30044674
MS. JESSICA WIGGINS
MISSION POOLS
22600-E Lambert St., Ste. 1104
Lake Forest, California 92630
SUBJECT: RESULTS OF ACOUSTICAL CERTIFICATION MEASUREMENT
FOR 1522 PEGASUS STREET -- CITY OF NEWPORT BEACH
Dear Ms. Wiggins:
We are pleased to inform you that the pool equipment installation located at 1522
Pegasus Street in the City of Newport Beach complies with the City's 55 dBA noise limit. No
additional noise mitigation is necessary.
The installation was measured on Tuesday, November 14, 2023, using a Larson Davis
Model 700 Type 2 Sound Level Meter. The installation was observed to consist of one Pentair
Intelliflo pump and a Jandy JXi heater, all located in a side yard setback.. The measurement
microphone was placed just over the top of the nearest property line wall directly opposite the
pool equipment. The measurement reported a level of 52 dBA with the pump and heater unit
operating simultaneously. This level complies with the City's 55 dBA noise limit.
Thank you, and if there are any questions, please do not hesitate to call.
BOX 2325
FULLERTON, CALIFORNIA • 92837
PHONE: 714-805-0115 1
P� idTe r
A Inc
ASTM C42 & ASTM C39 - Compressive Strength of Drilled Cores
Client Name: NAKOYA INSPECTIONS Project Name: Mission Pools
Inspector's Name: Alu Kabba Project Address: 1522 Pegasus St
Inspector's License No.: On File Newport Beach, CA
Field Identification: NR Permit Number: SM9-0147
Cast Data (Provided by Client)
Material Description:
SHOTCRETE PANEL I Core Sample
Set Number:
NR
Cast Date:
9/13/23
Number of Samples:
3
Cast By:
Alu Kabba
Total Yards:
40
Contractor:
NR
Cement Type:
NR
Material Supplier:
Associated Ready Mix
Cast Time:
9:30am
Plant:
NR
Mix Time:
NR
Mix Design Number:
S80000
Admixture:
NR
Ticket Number:
294009
Slump - In.:
2-1/2
Specified PSI:
4,500
Air Temperature:
NR
Design PSI:
4,500
Concrete Temperature:
NR
Location of Pour: Swimming Pool
Notes:
NR = Not Reported
Laboratory Compressive Strength Data
Date Specimen Received: 10/20/23
Date of Test: 10/20/23
Technician: On File
Equipment Used: FORNEY F-25EX-F-CPILOT
Calibration Date: 8/24/23
Specimen ID
Age of
Test
(Days)
Date of
Test
Time of
Test
Specimen Dimensions
Cross Sectional
Area - In.
Maximum
Load - Lbs.
F'c PSI
Fracture Type
1- In.
2 - In.
3 - In.
4 - In.
5 - In.
6 - In.
Height/Diameter
PT- 57438.1 •1
38
10/20/23
12:27 PM
3.73
3.74
-
10.96
58,180
5,098
2
5,94
5.95
1.59
PT- 57438.1 .2
38
10/20/23
12:30PM
3.73
3.73
-
10.93
55,500
4,877
4
5.88
5.89
1.58
PT- 57438.1 .3
38
10/20/23
12:33 PM
3.73
3.74
-
10.96
56,690
4,963
2
5.80
5.81
1.55
7—
Average F'c 38 — 4,979
Compliance with Specified Strength: THE AVERAGE 38-DAY COMPRESSIVE STRENGTH EXCEEDS THE SPECIFIED VALUE
Technician Comments:
Nate 2: Dimensions 1 and 2-Dlametam; Dimension" and 4= Capped Core Height; Dimensions $ and 6 = Uncapped Core Height
31 Note 3: COrnafth factor for h/d <1.75 applied per ASTM C42 (based an untapped height dlvlded by average diameter.)
Note 4: Fracture Type Deslgnatlon Per ASTM C39 Figure 2: 1- Cone, 2= Cone and crack, 3= Columnar, 4= Diagonal, S=Side Fracture, 6- Side Fradpre Point
Note 5: Results only relate to tested specimens.
8145 SECURA WAY, SANTA FE SPRINGS, CA 96676 1 OFFICE 424-263.5955 1 FAX 424-263.5987
WEB WWW.PYRAMIDTESTING.COM I EMAIL PYRAMIDTESTING@GMAIL•COM