HomeMy WebLinkAboutF2023-0076 - MiscCITY ��� ��� NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUIL1OOC��center Dr�e|F\D —.—'--~~^' . .""� '`'o8|Newport Beach, CAQ2O58-8815 FIRE ROUGH INSPECTION -__-_~~LI^.T YES "^ Drain valve b. 8ackflowdevice (single check) c. Bell activation device d. Inspector's test valve e R�aro�ad . per � 2. Pressure Test a. System tested at operating pressure for 2hours b. Pressure gauge installed 3. orinkler Heads shall not be Installed In the fittings prior to the fittings a. Installation and spacing of temporary test plugs 4. Etinq a. Material installed per plan b. Hangers per codes/prevent upward movement c. /U|CPVCoipinQmha|/be/nstoUmdbypereonovvhohewabeen certified bythe manufacturer for installation ufCPVCpiping d. Piping protected from damage 5 ' Bell o- Wiring installed per code b. Boxes Installed atproper locations El .NOTE: CPVCPlastic pipe /nthe garage shall not beexposed. Sprinklers that are U| ~ {3 do�° Response" ur"Residentiol"must bmused, � CORRECTIONS AND NOTES: FIRE SPRINKLER NFPA13D SYSTEM ROUGH INSPECTION APPROVED: BY: ROL J PERMIT#: PZ-01-3,Q go mrm*pfreSprinkler wnw13mSYstern'nOUo Inspection Checklist 05/12/2015 ITY-OF NEW PORT BFI"H CONDRTNITY DEVELOPMENT DEPARTMENT BUILDWG DMSION '44 100 civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8916 IMF 0 1 L www,newportbeachca.gov 1. (949) 644-3200 FIRE SPRINKLER NFPA 13D SYSTEM FINAL CIUCKLIST (RESIDENTIAL) YES NO i, Water meter proper size 2. Fire sprinkler system Installed per the approved plans ❑ 3. All construction covers removed -from sprinkler heads ❑ 4. Cover plates are NOT to be Installed, but shall be available on the jobsite ❑ 5. All tape and paint removed from sprinkler heads El 6. Finish trim Installed around sprinkler heads E I 7. Proper signage posted at all required locations I I ❑ 8. Flow test conducted and bell tested E I ❑ 9. Location of inspector's testing valve in approved location f El SYSTEM-. 10, Clearances around sprinkler heads and riser - no obstructions ❑ 11, Operating pressure gauge installed at riser showing proper water pressure I F-I 12. Back flow preventer installed 0 13. System Installed per manufacturers specifications I R NOTES: FIRE SPRINKLER NFPA 13D SYSTEM FINAL APPROVED: 1- 00 #7 L I/ PERMIT #:� J� �jo BY: ZI W DATE: -- Forms\ Fire sprinkler NFPA 13D System - FINAL Checklist RnIDENTIAL 05/12/2015